This shows you the differences between two versions of the page.
| Next revision | Previous revision | ||
|
laws:fmivp [2019/09/17 16:31] helene created |
laws:fmivp [2020/08/25 15:46] (current) |
||
|---|---|---|---|
| Line 27: | Line 27: | ||
| ==== Real parameters ==== | ==== Real parameters ==== | ||
| - | ^ Line 1 (5G10.0/6G10.0 ) ^^ | + | ^ Line 1 (5G10.0) ^^ |
| |COEFK|K penalty coefficient| | |COEFK|K penalty coefficient| | ||
| |ALPHA|Mass transfer coefficient $\left[m/s\right]$| | |ALPHA|Mass transfer coefficient $\left[m/s\right]$| | ||
| Line 47: | Line 47: | ||
| 3 | 3 | ||
| ==== Meaning ==== | ==== Meaning ==== | ||
| - | |SIG(1)|=water output or input flow at the boundary| | + | |SIG(1)|water output or input flow at the boundary| |
| - | |SIG(2)|=gas output or input flow at the boundary| | + | |SIG(2)|gas output or input flow at the boundary| |
| - | |SIG(3)|=temperature output or input flow at the boundary| | + | |SIG(3)|temperature output or input flow at the boundary| |
| ===== State variables ===== | ===== State variables ===== | ||
| Line 56: | Line 56: | ||
| ==== List of state variables ==== | ==== List of state variables ==== | ||
| |Q(1)| = 0 | | |Q(1)| = 0 | | ||
| - | |Q(2)| = porous surface relative humidity| | + | |Q(2)|porous surface relative humidity| |
| - | |Q(3)| = drying air relative humidity | | + | |Q(3)|drying air relative humidity | |
| - | |Q(4)| = total water flow | | + | |Q(4)|total water flow | |
| - | |Q(5)| = evaporation flow | | + | |Q(5)|evaporation flow | |
| The total water flow boundary condition is expressed as the sum of the seepage flow and vapour exchange flow | The total water flow boundary condition is expressed as the sum of the seepage flow and vapour exchange flow | ||