User Tools

Site Tools


elements:conra

This is an old revision of the document!


CONRA

Description

2D boundary. The element is used to model convection and radiation between the structure and the environment. It is defined by 1, 2, or 3 “real” nodes and 1 node representing the environment.
It can only be used with laws RACO and COPO1 (for pollution problems).

If the element is connected to a RAYON element, it must have 3 nodes.

For pollution problems, these elements must be defined last.

Type: 111 Implemented by: R. Charlier, 1982

Files

Prepro: CONRAA.F
Lagamine: CONRAB.F

Input file

TITLE (A5)
TITLE“CONRA” in the first five columns
Line 2 (2I5)
NELEM Number of elements
NNODE Total number of nodes (environment included)
Definition of the elements (5I5/4I5)
NINTENumber of integration points:
2 or 3 for NNODE > 2
1 for NNODE = 2
LMATE Material
NPOND Ponderation index
= 0 for classic use (law RACO1)
= 1 for Upwind elements in a pollutant transport problem (law COPO1), in that case NNODE must be equal to 2: one node that belongs to the convection-diffusion elements (CONV2, ADVE2, ELAN2) and one environment node.
NCOELNumber of elements related to true nodes (1 to 4) - see Note (1)
ICAS For each NCOEL one must detail the topology of the related elements - see Note (1)
NODES List of nodes (4, 3 or 2) see figure 1

Remark: For a Eulerian Lagrangian analysis of pollution, the environment node must be positioned outside the structure.
Fig. 1

Results

Sigma(1)First part of the total flux (convection + radiation taken by diffusion in the domain)
Sigma(2)Second part of the flux (taken by convection in the domain)

(1) Explanation on NCOEL and ICAS

  • For the classic use: NCOEL = ICAS = 0
  • For a Eulerian Lagrangian analysis of pollution, NCOEL = 4 and ICAS = 0
  • For FUPG analysis of pollution, distinction between the following topologies:
NCOEL = 1
1 solid element connected
to the real node
NCOEL = 2
2 solid elements connected
to the real node
NCOEL = 3
3 solid elements connected
to the real node
NCOEL = 4
4 solid elements connected
to the real node
2 solid elements connected
to the real node

Treated like the case
NCOEL = 4 & ICAS = 0