Test 36: EHMIC_HMIC unsaturated gas injection (pw fixed)

EHMIC_HMIC
Created byGilles Corman
Reference solution date01-03-2023
Files (.rar)RAR files
Description
Simulation Pressure-controlled gas injection test (pg = 0.1MPa → 1MPa) with fixed water pressure (pw = 0.6MPa) through a clay-based material using the multi-scale EHMIC element with HMIC law.
Type (Mini or Big)Mini
Law/Element to be checked HMIC/EHMIC
Type of result (local): stress, state variable,..Water and gas pressures, water and gas fluxes, water and gas storages, gaseous gas total flux, water vapour flux, dissolved gas total flux, dissolved gas diffusive flux, dissolved gas advective flux at several times along the column
Type of result (global): temperature, force,.. /
Result file IPN file
Node displacement history (XYZT) /
Strategy options
PRECF
PRECU
Time (1 CPU)/
Time (more than 1 CPU) 0h.12m.39s.
Total number of steps2177
Total number of iterations7326
Used solver (4 or 8)4