User Tools

Site Tools


battery:listtests:test35

Test 35: EHMIC_HMIC saturated gas injection (pw released)

EHMIC_HMIC
Created byGilles Corman
Reference solution date01-03-2023
Files (.rar)RAR files
Description
Simulation Pressure-controlled gas injection test (pg = 1MPa → 3MPa) with released water pressure (pw = 5MPa) through an initially saturated clay-based material using the multi-scale EHMIC element with HMIC law.
Type (Mini or Big)Mini
Law/Element to be checked HMIC/EHMIC
Type of result (local): stress, state variable,..Water and gas pressures, water and gas fluxes, water and gas storages, gaseous gas total flux, water vapour flux, dissolved gas total flux, dissolved gas diffusive flux, dissolved gas advective flux at several times along the column
Type of result (global): temperature, force,.. /
Result file IPN file
Node displacement history (XYZT) /
Strategy options
PRECF
PRECU
Time (1 CPU)/
Time (more than 1 CPU) 0h. 0m.22s.
Total number of steps89
Total number of iterations275
Used solver (4 or 8)4
battery/listtests/test35.txt · Last modified: 2023/12/13 09:33 by gilles